| RS232 / UPB
| 3
| Report
| UMI-32-W I/O Module (UPB technology, via UMC-DB9-W, 36A00-1, or Omni)
| RS232 / RF
| 1
| Report
| All Z-Wave-compatible door/window sensors
(e.g.
HomeManageables HM-DW001 Door/Window Sensor &
Hawking HRDS1)
Monitored via the
VRC0P-1LW or
the Omni.
| SNMP | - | Report | All SNMP sensors (supported by both ECS and the Barionet)
| Ethernet | - | Poll | All ModBus/RTU-compatible sensors (TCP/IP) / various
| RS232 | - | Poll | All ModBus/RTU-compatible sensors (serial) / various
| RS232 | - | Report | All MetaSys (N2 Open) compatible inputs / various
| Ethernet | 1-300 | Report | Barionet / Barix
| | Ethernet | 12 | Report | Barix IO12 (via the Barionet) / Barix
| | Ethernet | 2 | Report | BC4/BCX-1 / BitWise Controls
| | RS232 | 15 | Report | D1700 Series (D1701, D1702, D1711, D1712) / DGH
| RS232 | 15 | Report | D1700M Series (D1711M, D1712M) / DGH
| RS232 | 24 | Report | H1700 Series (H1750) / DGH
| RS232 | 64 | Report | H1700 Series (H1770) / DGH
| RS232 | 24 | Report | H1700M Series (H1750M) / DGH
| RS232 | 64 | Report | H1700M Series (H1770M) / DGH
| RS232 | 3 | Poll |
485SDA12,
232SDA12
/ B&B Electronics
| RS232 | 1-16 | Poll |
485SDD16,
232SDD16
/ B&B Electronics
| RS232 | 2 | Poll |
232SPDA
/ B&B Electronics
| RS232 | 1 | Report | DS10A door/window sensor (X10, via the W800RF32 / W800USB) / X10
| RS232 | 1...215 | Report | Omni, Omni-II, OmniLT, OmniPro, OmniPro-II (RS232 only) / HAI
| RS232 | 8 | Poll |
SeaI/O-470S,
SeaI/O-520S
/ SeaLevel
| RS232 | 16 | Poll |
SeaI/O-410S
SeaI/O-420S
/ SeaLevel
| RS232 | 32 | Poll |
SeaI/O-430S
/ SeaLevel
| RS232 | 96 | Poll |
SeaI/O-462S,
SeaI/O-463S
/ SeaLevel
| RS232 | 8 | Poll | AC256 / Andover Controls
| SNMP | 2-8 | Report | Security Sensors with
SensorProbe2,
SensorProbe8,
SensorProbe8-X20, or
SensorProbe8-X60
/ AKCP
| SNMP | 2-8 | Report | Dry Contact Sensors with
SensorProbe2,
SensorProbe8,
SensorProbe8-X20, or
SensorProbe8-X60
/ AKCP
| SNMP | 2-8 | Report | 10 Dry Contact Inputs with
SensorProbe2,
SensorProbe8,
SensorProbe8-X20, or
SensorProbe8-X60
/ AKCP
| SNMP | 2-8 | Report | Dry Contact Sensor with
SH-2+,
SHPro, or
SDC-2+2 / Uptime Devices
| SNMP | 1 | Report | Security Sensor with
SH-2+,
SHPro, or
SDC-2+2 / Uptime Devices
| SNMP | 4 | Report | Enviromux-Mini / Network Technologies
| RS232 | 16 | Latched | SECU-16 (ADICON, not recommended due to a bug in module's firmware) / Applied Digital
| RS232 | 16 | Latched | SECU-16I (ADICON, not recommended due to a bug in module's firmware) / Applied Digital
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |